Products
Subcategories
-
Advanced sensors
<p>Advanced sensors</p> -
Electrical parts
<p>Electrical cabinets, automatic fuses, process sensors, data cables, electrical cables, connectors, contactors, relays, electric motors</p> -
Mechanical Parts
<p>Springs, connecting rods, bearings, linear guides, rotary fittings, fasteners, belts, mechanical components</p> -
Pneumatic
<p>Valves, island valves, pneumatic actuator, cylinders, connecting plates, magnet coils, control distributors</p> -
Tools
<p>Hammers, pliers, axes, screwdriver kits, bits, masonry tools. drilling machines, angle grinders, car tools</p> -
Home and Garden
<p>Cleaning materials, gardening tools, buckets, wheelbarrows, mops, cloths, detergents</p> -
Safety
<p>Safety equipment</p> -
Auto
<p>Power tools, batteries, engine repairs, body repairs, cylinder head repairs.</p> -
Measuring and control...
<p>Measuring, checking, checking gauges.</p>
-
Digital Coupling Module KBD-1
€23.00In building automation, as well as in process control, it is very practical to switch a relay contact on or off during commissioning and service. This means operating a valve, a pump, heating or ventilation in manual mode. With the switch feedback, the controller is informed whether the coupling module is in automatic or manual mode.
The KBD-1 coupling module contains 1 circuit with 1 changeover contact for a load of 12 A / 250 V AC, which can be controlled with 24V AC/DC.
-
Digital Coupling Module KBD-1/L
€30.28Switching on lights can lead to very high inrush
current peaks.
A closing contact can bounce 3 to 7 times until it has
closed completely. This creates a light arc which can
melt the contact surface. Micro-welding can take
place when the contact cools down (contact sticks).
To prevent sticking of the contact, relays with a
preceding tungsten contact are used.
Inrush current peaks for filament lamps of 165 A /
max. 20 ms, or for fluorescent lamps of 800 A / max.
200 µs can be switched with these.
-
Digital Coupling Module KBD-1/M
€23.00• 1 switching circuit with 12 A The switching circuit is capable of switching an output of 12 A /250 V AC. • Minus activation For the new generation of controllers with minus outputs, the A3 activation is activatable with a minus.
• AUTO-OFF-ON with feedback The switching circuit can switch to automatic or manual mode. In automatic mode the contact with feedback is closed, therefore a logic 1 results on the controller. Multiple feedbacks can be connected in series.
• DIN 45 mm housing The standardised housing enables the KBD-1 to be installed by means of a 45 mm cut-out behind the covering, it only requires a width of 17.5 mm for this. It only requires a width of 17.5 mm.
-
Digital Coupling Module KBD-2
€40.62In building automation, as well as in process control, it is very practical to switch a relay contact on or off during commissioning and service. This means operating a valve, a pump, heating or ventilation in manual mode. With the switch feedback, the controller is informed whether the coupling module is in automatic or manual mode.
The KBD-2 coupling module contains 2 circuits, each with 1 changeover contact for a load of 12 A / 250 V AC, which can be controlled with 24V AC/DC.
-
Digital Coupling Module KBD-2/L
€55.38Switching on lighting fixtures can result in very high inrush currents. A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.
An 8-pole connection comb is available for faster wiring of the supply A1 – A2.
-
Digital Coupling Module KBD-2/M
€40.61• 2 independent circuits with 12 A
Every separately controllable switching circuit is
capable of switching an output of 12 A / 250 V AC.
• Minus activation
For the new generation of controllers with minus
outputs, the A3 and A4 activations are activatable
with a minus.
• AUTO-OFF-ON with feedback
The switching circuit can switch to automatic or
manual mode. In automatic mode the contact with
feedback is closed, therefore a logic 1 results on
the controller. Multiple feedbacks can be connected in series.
• DIN 45 mm housing
The standardised housing enables the coupling
module to be installed by means of a 45 mm cutout behind the covering, it only requires a width of
17.5 mm (8.75 mm per channel) for this.
-
Digital watchdog WDR-2
€71.752-channel digital watchdog coupling module with predefined switching action in the event of a controller failure.
-
DIN relay coupler DRK-1/L
€24.90Switching on lighting fixtures can result in very high inrush currents. A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.
An 8-pin connection comb is available for quick wiring of the negative pole A2.
-
DIN relay coupler DRK-2/L
€44.41Switching on lighting fixtures can result in very high inrush currents. A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.
An 8-pin connection comb is available for quick wiring of the negative pole A2.
-
DIN-relay coupler DRK-1
€17.51· 1 switching circuit with 12 A
The switching circuit is capable of switching an
output of 12 A / 250 V AC.
· DIN 45 mm housing
The standardised housing enables the DIN-relay
coupler to be installed by means of a 45 mm cutout behind the covering; it only requires a width of
17.5 mm for this. The switching status indicator
(LED) is clearly visible, with the connections
located in a protected position behind the cover
panel.
-
DIN– Relay coupler DRK-2
€29.22· 2 independent circuits with 12 A
Every separately controllable switching circuit is
capable of switching an output of 12 A / 250 V AC.
· DIN 45 mm housing
The standardised housing enables the DIN-relay
coupler to be installed by means of a 45 mm cutout behind the covering; it only requires a width of
17.5 mm for this. The switching status indicators
(LED) are clearly visible, with the connections
located in a protected position behind the cover
panel.
-
Diode Module DMA-11
€25.10• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DME-6
€20.26• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DMK-11
€21.83• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DMS-5
€23.31• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.
-
Display module for SHD/ SHD-SD/ SHD 692
€294.77The special PREMASGARD® LCD - SHD accessory for displaying the differential pressure is compatible with SHD / SHD - SD / SHD 692 type pressure sensors.
The display module is mounted below the angle plug acc. to DIN EN 175301-903-A and has a three-digit liquid crystal display that can be turned and tilted to the ideal reading position regardless of the installation position. The module is pre-configured and calibrated at the factory.