Electrical parts
Electrical cabinets, automatic fuses, process sensors, data cables, electrical cables, connectors, contactors, relays, electric motors
Subcategories
-
3-phase Monitoring DUW-32
€77.44The three-phase monitoring relay DUW-32 monitors the
three-phase mains for the correct phase sequence as
well as for failure of a phase.
The device is supplied by the measuring circuit L1 – L2
– L3 – (N). The output relay is pulled up in normal
operation. The output relay drops out if the phase
sequence is violated, a phase fails or the voltage drops
below 75% of the rated voltage. The error is displayed
by the red LED. In order to bypass brief mains faults,
the off time t2 can be delayed by 0.1 to 10 seconds with
the potentiometer
-
3-phase Monitoring DUW-32/N
€77.44The three-phase monitoring relay DUW-32 monitors the
three-phase mains for the correct phase sequence as
well as for failure of a phase.
The device is supplied by the measuring circuit L1 – L2
– L3 – (N). The output relay is pulled up in normal
operation. The output relay drops out if the phase
sequence is violated, a phase fails or the voltage drops
below 75% of the rated voltage. The error is displayed
by the red LED. In order to bypass brief mains faults,
the off time t2 can be delayed by 0.1 to 10 seconds with
the potentiometer
-
3-phase Monitoring DUW-41
€100.22The three-phase monitoring relay DUW-41 monitors
the three-phase mains for overvoltage and undervoltage, the correct phase sequence as well as for failure of a phase .
The device is supplied by the measuring circuit L1 – (N)
– L2 – L3. The output relay is pulled up in normal operation. The output replay drops out at overvoltage or
undervoltage, failure of a phase and phase sequence
violation. The error is displayed by the red LED. In order
to bypass brief mains faults, the off time t can be delayed by 0.5 to 10 seconds with the potentiometer
-
3-phase Monitoring DUW-41/N
€100.22The three-phase monitoring relay DUW-41 monitors
the three-phase mains for overvoltage and undervoltage, the correct phase sequence as well as for failure of a phase .
The device is supplied by the measuring circuit L1 – (N)
– L2 – L3. The output relay is pulled up in normal operation. The output replay drops out at overvoltage or
undervoltage, failure of a phase and phase sequence
violation. The error is displayed by the red LED. In order
to bypass brief mains faults, the off time t can be delayed by 0.5 to 10 seconds with the potentiometer
-
Analogue Coupling Module KBA-1 / KBAi-1
€36.92• Analogue manual mode
The coupling module can be switched over to manual mode. This allows an analogue signal of 0 - 10 V
or 0 - 20 mA to be generated independently of a
controller.
• AUTO-OFF-ON with feedback
The coupling mode can switch to automatic or
manual mode. In automatic mode the contact with
feedback is closed, therefore a logic 1 results on the
controller. Multiple feedbacks can be connected in
series.
• DIN 45 mm housing
The standardised housing enables the coupling
module to be installed by means of a 45 mm cutout
behind the covering, it only requires a width of 17.5
mm for this.
-
Analogue Watchdog WDA-1
€67.51• Analogue manual or emergency operation
The coupling module can switch to manual or
watchdog mode. This allows an analogue signal of
0 - 10 V to be generated independently of a
controller.
• DIN 45 mm housing
The standardised housing enables the coupling
module to be installed by means of a 45 mm cutout behind the covering; it only requires a width of
17.5 mm for this.
-
Asymmetrical Clock Generator ATG-1
€56.97The asymmetrical clock generator ATG-1 contains
1 changeover contact for a load of 16 A / 250 V AC.
The narrow, 17.5-mm DIN housing saves space in the
switching cabinet and has a high switching capacity.
The pulse and pause times can be set differently from
0.1 s to 100 days.
The multiple-voltage power supply facilitates operation with all voltages ranging from 12 V to 240 V AC /
DC
-
Automatic staircase lighting TLA-1
€33.97The automatic staircase lighting TLA-1 switches on the lighting for the preset time by pressing a button. Even if the keys are blocked, the device switches off after the set time without being damaged. The lighting time can be set from 0.5 minutes to 10 minutes. It is possible to connect buttons with glow lamps.
-
Automatic staircase lighting TLA-1/L
€44.84Switching on lighting fixtures can result in very high inrush currents.
A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
With this switch-on peaks of fluorescent lamps with electronic ballasts and LEDs of 800 A / 200 µs or incandescent lamps of 165 A / max. 20 ms can be switched.
-
Automatic staircase lighting TLA-4
€47.26The automatic staircase lighting TLA-4 includes 4 different operating modes, which can be set using the rotary switch on the front.
With functions a, b, the operating time can be repeatedly extended by briefly pressing the control button(s). Each short press multiplies the time set by the potentiometer. The maximum value of the activation time thus extended is a maximum of 30 minutes, regardless of the number of presses.
-
-
-
-
-
-
-
-
-
-
Bistable installation contactor ISB-220-11
€21.10The bistable installation contactors are only switched on and off with a pulse or manually. When switched, the coil does not consume any power and therefore does not cause any additional heat in the control cabinet.
The double-breaking contacts increase switching reliability. They are therefore suitable for switching all types of electrical loads such as: electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and a wide variety of types of lighting.
-
Bistable installation contactor ISB-220-20
€21.10The bistable installation contactors are only switched on and off with a pulse or manually. When switched, the coil does not consume any power and therefore does not cause any additional heat in the control cabinet.
The double-breaking contacts increase switching reliability. They are therefore suitable for switching all types of electrical loads such as: electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and a wide variety of types of lighting.
-
Bistable installation contactor ISB-232-11
€25.30The bistable installation contactors are only switched on and off with a pulse or manually. When switched, the coil does not consume any power and therefore does not cause any additional heat in the control cabinet.
The double-breaking contacts increase switching reliability. They are therefore suitable for switching all types of electrical loads such as: electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and a wide variety of types of lighting.
-
Bistable installation contactor ISB-232-20
€25.30The bistable installation contactors are only switched on and off with a pulse or manually. When switched, the coil does not consume any power and therefore does not cause any additional heat in the control cabinet.
The double-breaking contacts increase switching reliability. They are therefore suitable for switching all types of electrical loads such as: electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and a wide variety of types of lighting.
-
Bistable installation contactor ISB-420-22
€31.65The bistable installation contactors are only switched on and off with a pulse or manually. When switched, the coil does not consume any power and therefore does not cause any additional heat in the control cabinet.
The double-breaking contacts increase switching reliability. They are therefore suitable for switching all types of electrical loads such as: electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and a wide variety of types of lighting.