AERASGARD® RFTM-PS-CO2

€521.44
Tax included

Maintenance-free AERASGARD® RPS - SD room air quality measuring transducer with active output, in an elegant plastic housing with snap-on cover, base with 4-hole attachment, for detecting the particulate matter (PM) content (0...500 g/m3).

The transmitter converts the measurand into a standard signal of 0-10 V (fixed).

Maintenance-free, multifunctional AERASGARD® RFTM - PS - CO2 - W room air quality measuring transducer with active/switching output, automatic calibration, in an elegant plastic housing with snap-on cover, base with 4-hole attachment, optionally with/without display, for detecting air humidity (0...100% r.H.), temperature (0...+50°C), particulate matter (PM)

Display
Measured variables
AERASGARD, RHEASGARD & RHEASREG
Quantity

Long-term stability (PM)

± 1.25 g/m3 (± 1.25 % of measured value/year)

Measuring accuracy (PM)

typically ± 10 g/m3 (± 10 % of measured value) at PM 2.5

typically ± 25 g/m3 (± 25 % of measured value) at PM 10

Measuring range (PM)

0... 50 g/m³ 0...100 g/m³ 0...300 g/m³ 0...500 g/m³

Particle size (PM)

PM 2,5 (0,3...2,5 m); PM 10 (0,3...10 m)

Voltage supply

24 V AC/ DC (± 10 %)

Power consumption

RPS-SD: < 1.5 W/ 24 V DC typical;

< 2.9 VA/ 24 V AC typical;

peak current 200 mA

RFTM-PS-CO2-W: < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical;

peak current 200 mA

Measuring range, humidity

0...100 % r. H.

Operating range, humidity

0...95 % r. H. (without dew formation)

Deviation of humidity

typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 %

Output, humidity

0 -10 V or 4...20 mA (selectable via DIP switches)

Measuring range, temperature

0...+ 50 °C (output equivalent to 0 -10 V or 4...20 mA)

Operating range, temperature

0...+50 °C

Temperature deviation

typically ± 0.2 K at +25 °C

Output, temperature

0 -10 V or 4...20 mA (selectable via DIP switches)

Service life

> 60 months (under normal load conditions)

depending on the type of loading and gas concentration

Measuring range, CO2

0...2000 ppm or 0...5000 ppm (selectable via DIP switches)

Sensor, CO2

Optical NDIR sensor (non-dispersive infra-red technology),

with manual calibration (via zero button),

with automatic calibration (can be deactivated via DIP switches)

Output, CO2

0 -10 V or 4...20 mA (selectable via DIP switches)

Measuring accuracy, CO2

typically ± 30 ppm ± 3 % of measured value

Temperature dependence, CO2

± 5 ppm/ °C or ± 0.5 % of measured value/ °C

(whichever is higher)

Pressure dependence

± 0,13 %/ mm Hg

Gas exchange

by diffusion

Relay output

with potential-free changeover contact (24 V / 1 A)

(assignment selectable via DIP switches, switchpoint adjustable)

Warm up time

approx. 1 hour

Response time

< 2 minutes

Output

0 -10 V or 4...20 mA (selectable via DIP switches,

selected variant applies for all outputs), working resistance < 800 Ω

Output

0 -10 V or 4...20 mA, working resistance < 800 Ω

(selectable via DIP switches, selected variant applies for all outputs),

with offset potentiometer (± 10 % of the measuring range)

Ambient temperature

0...+50 °C

Electrical connection

0.14 - 1.5 mm² via terminal screws

Housing

plastic, material ABS,

colour pure white (similar to RAL 9010)

Dimensions

98 x 98 x 33 mm (Baldur 2)

Installation

wall mounting or on in-wall flush box, Ø 55 mm,

base with 4 holes, for attachment to vertically or

horizontally installed in-wall flush boxes for rear cable entry,

with predetermined breaking point for cable entry

from top/ bottom in case of plain on-wall installation

Long-term stability

< 2 % in 15 years

Protection class

III (according to EN 60 730)

Protection type

IP 30

1501-2116-7321-000