Digital Coupling Module KBD-2/M
€40.61• 2 independent circuits with 12 A
Every separately controllable switching circuit is
capable of switching an output of 12 A / 250 V AC.
• Minus activation
For the new generation of controllers with minus
outputs, the A3 and A4 activations are activatable
with a minus.
• AUTO-OFF-ON with feedback
The switching circuit can switch to automatic or
manual mode. In automatic mode the contact with
feedback is closed, therefore a logic 1 results on
the controller. Multiple feedbacks can be connected in series.
• DIN 45 mm housing
The standardised housing enables the coupling
module to be installed by means of a 45 mm cutout behind the covering, it only requires a width of
17.5 mm (8.75 mm per channel) for this.
-
Digital watchdog WDR-2
€71.752-channel digital watchdog coupling module with predefined switching action in the event of a controller failure.
-
DIN relay coupler DRK-1/L
€24.90Switching on lighting fixtures can result in very high inrush currents. A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.
An 8-pin connection comb is available for quick wiring of the negative pole A2.
-
DIN relay coupler DRK-2/L
€44.41Switching on lighting fixtures can result in very high inrush currents. A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).
To avoid contact sticking, relays with a leading tungsten contact are used.
This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.
An 8-pin connection comb is available for quick wiring of the negative pole A2.
-
DIN-relay coupler DRK-1
€17.51· 1 switching circuit with 12 A
The switching circuit is capable of switching an
output of 12 A / 250 V AC.
· DIN 45 mm housing
The standardised housing enables the DIN-relay
coupler to be installed by means of a 45 mm cutout behind the covering; it only requires a width of
17.5 mm for this. The switching status indicator
(LED) is clearly visible, with the connections
located in a protected position behind the cover
panel.
-
DIN– Relay coupler DRK-2
€29.22· 2 independent circuits with 12 A
Every separately controllable switching circuit is
capable of switching an output of 12 A / 250 V AC.
· DIN 45 mm housing
The standardised housing enables the DIN-relay
coupler to be installed by means of a 45 mm cutout behind the covering; it only requires a width of
17.5 mm for this. The switching status indicators
(LED) are clearly visible, with the connections
located in a protected position behind the cover
panel.
-
Diode Module DMA-11
€25.10• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DME-6
€20.26• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DMK-11
€21.83• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
Diode Module DMS-5
€23.31• Diodes 1N4007
The diodes have a forward off-state voltage of
1,000 V and a forward current of max. 1A.
• Different variants
Different variants of the diode modules are produced: Module with individually wirable diodes,
module with common anode or common cathode,
module with group input and group output for
lamp control and group alarm, for example.
• DIN 45 mm housing
The standardised housing enables the diode module to be installed by means of a 45-mm cutout
behind the covering; it only requires a width of
17.5 mm for this.
-
EPU-41 monitoring relay
€69.31The EPU-41 monitoring relay monitors the voltage level in the 1-phase network for overvoltage and undervoltage, as well as for phase failure. The monitored voltage is also the
power supply for the device. In normal operation, the output relay is picked up. In the event of overvoltage or undervoltage, or if the phase fails, the output relay drops out. The over- or undervoltage is indicated by the red LED. In order to temporarily bridge brief disturbances on the network, the switch-off time t can be delayed from 0 to 10 seconds using the potentiometer.
-
EPU-42 monitoring relay
€79.44The EPU-42 monitoring relay monitors the voltage level in the 1-phase network for overvoltage and undervoltage. The monitored voltage is also the power supply for the device. In normal operation, the output relays are switched off. In the event of overvoltage, relay 1 switches on, and in the event of undervoltage, relay 2 switches on. The red and green LED displays clearly indicate the error status. In order to temporarily bridge brief disturbances on the network, the response time t can be delayed from 0 to 10 seconds with the potentiometer.
-
Frost Protection Signal Transmitter FSG-10
€36.93• 10 V continuous signal
Conversion of the 24 V AC/DC signal into a 10 V DC
continuous signal. The continuous signal can be
loaded with up to 5 mA.
• DIN 45 mm housing
The standardised housing enables the frost protection signal transmitter to be installed by means of a
45 mm cutout behind the covering; it only requires
a width of 17.5 mm for this.
-
Industrial relay RE403ALTU
€7.71The classic industrial relay with an 11-pin socket is increasingly being replaced by the slimmer, small industrial relay. In addition to the size and the lower price, it has the additional advantage that it has 4 changeover contacts. Even the standard version of the small industrial relays includes a mechanical and an optical (LED) switching status display, as well as a protective circuit (freewheeling diode) for DC coils. The integrated, lockable test button enables a system to be tested very easily during commissioning or when servicing is required. In addition to the standard screw base, there are also those with logical separation and bases with spring-loaded terminals to choose from. All sockets can be equipped with additional circuit modules.
-
Industrial relay RE403DVTU
€8.12The classic industrial relay with an 11-pin socket is increasingly being replaced by the slimmer, small industrial relay. In addition to the size and the lower price, it has the additional advantage that it has 4 changeover contacts. Even the standard version of the small industrial relays includes a mechanical and an optical (LED) switching status display, as well as a protective circuit (freewheeling diode) for DC coils. The integrated, lockable test button enables a system to be tested very easily during commissioning or when servicing is required. In addition to the standard screw base, there are also those with logical separation and bases with spring-loaded terminals to choose from. All sockets can be equipped with additional circuit modules.
-
Industrial relay RE409ALTU
€8.12The classic industrial relay with an 11-pin socket is increasingly being replaced by the slimmer, small industrial relay. In addition to the size and the lower price, it has the additional advantage that it has 4 changeover contacts. Even the standard version of the small industrial relays includes a mechanical and an optical (LED) switching status display, as well as a protective circuit (freewheeling diode) for DC coils. The integrated, lockable test button enables a system to be tested very easily during commissioning or when servicing is required. In addition to the standard screw base, there are also those with logical separation and bases with spring-loaded terminals to choose from. All sockets can be equipped with additional circuit modules.
-
Installation contactor ISU-220
€26.37Installation contactors are used in switch cabinets in building technology such as residential buildings, office buildings, restaurants and hotels, shopping centers and hospitals, as well as in industrial applications, production facilities, logistics and storage technology.
They are used for the automatic control of electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and in lighting technology.
-
Installation contactor ISU-220-02
€26.37Installation contactors are used in switch cabinets in building technology such as residential buildings, office buildings, restaurants and hotels, shopping centers and hospitals, as well as in industrial applications, production facilities, logistics and storage technology.
They are used for the automatic control of electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and in lighting technology.
-
Installation contactor ISU-220-11
€26.37Installation contactors are used in switch cabinets in building technology such as residential buildings, office buildings, restaurants and hotels, shopping centers and hospitals, as well as in industrial applications, production facilities, logistics and storage technology.
They are used for the automatic control of electrical devices and units, AC and three-phase motors, pumps, air conditioning systems, electrical heaters and in lighting technology.
-
Installation Relay ISR1-316
€47.11The installation relay ISR1-316 contains 3 changeover
contacts for a 16 A / 250 V AC load.
The narrow, 17.5-mm DIN housing saves space in the
switching cabinet and has a high switching capacity.
It can be operated with a supply voltage of 230 V AC
or 24 V AC/DC and has a built-in protection diode and
interference suppression capacitor.
-
Installation Relay ISR1-316/24
€39.68The installation relay ISR1-316 contains 3 changeover
contacts for a 16 A / 250 V AC load.
The narrow, 17.5-mm DIN housing saves space in the
switching cabinet and has a high switching capacity.
It can be operated with a supply voltage of 230 V AC
or 24 V AC/DC and has a built-in protection diode and
interference suppression capacitor.
-
Installation relay ISR2-216
€45.78The installation relay ISR2-216 contains 2 changeover contacts for a load of 16A / 250 V AC, which can be controlled separately.
The 17.5 mm narrow DIN housing saves space in the control cabinet, so a circuit only needs 8.75 mm.
Each individual relay can be operated separately with the supply voltages 230 V AC and 24 V AC/DC. They have a built-in protection diode and interference suppression capacitor.
-
Inverse isolating amplifier RB6250
€241.60The universal isolating amplifier RB 6250 is used for galvanic isolation and conversion of industry standard signals with an inverse characteristic. It can be used flexibly thanks to the simple range switching of the 144 possible signal combinations, the new universal power pack and the compact design. The high level of reliability and safe separation are further features that make the RB 6250 unrivaled.
The desired input and output measuring ranges to which the device is factory-calibrated can be specified with an order code. These can be easily reconfigured at any time using DIP switches. Subsequent readjustment or a measurement path comparison is possible using the zero/span potentiometers on the front.
-