Process sensors
Process sensors
Subcategories
-
Temperature
<p>Temperature sensor</p> -
Pressure
<p><span class="VIiyi" xml:lang="en" lang="en"><span class="JLqJ4b ChMk0b"><span>Pressure sensors</span></span></span></p> -
Humidity
<p>Humidity sensors</p> -
Light
<p>Light sensors</p> -
Flow
<p>Flow sensors</p> -
Analytical
<p>Analytical sensors</p> -
Level
<p>Level sensors</p> -
Air quality
<p>Air quality sensors</p>
-
CO2 sensor for schools | CO2 traffic light AERASGARD® RCO2-AS
€216.13Maintenance-free AERASGARD® RCO2-AS xx CO2 detector with traffic-light indicator and acoustic signal, self-calibrating, in an attractive plastic housing, for determining the CO2 content of the room air (0...3000 ppm). The measuring transducer converts the measurand to a standard signal, which is directly visualised by colour LEDs (traffic light indicator). An additional signal tone sounds when warning levels are reached (can be switched off via DIP switch).
-
Condensation control switch HYGRASREG® KW
€146.94The sensor device is installed on cooling ceilings, cooling or cold-water pipes and cooled surfaces, and has been designed to prevent the formation of condensation. It reliably detects the formation of dew by means of its humidity and temperature sensor (no conductivity measurement). Thanks to its measuring method of pro-dynamic cross-convection it yields precise measuring results (with LED status indicator). Dew point temperature is the temperature at which the air reaches the state of saturation and water vapour starts to condensate.
-
Condensation control switch HYGRASREG® KW
€123.88The sensor device is installed on cooling ceilings, cooling or cold-water pipes and cooled surfaces, and has been designed to prevent the formation of condensation. It reliably detects the formation of dew by means of its humidity and temperature sensor (no conductivity measurement). Thanks to its measuring method of pro-dynamic cross-convection it yields precise measuring results (with LED status indicator). Dew point temperature is the temperature at which the air reaches the state of saturation and water vapour starts to condensate.
-
Condensation control switch HYGRASREG® KW
€120.98The sensor device is installed on cooling ceilings, cooling or cold-water pipes and cooled surfaces, and has been designed to prevent the formation of condensation. It reliably detects the formation of dew by means of its humidity and temperature sensor (no conductivity measurement). Thanks to its measuring method of pro-dynamic cross-convection it yields precise measuring results (with LED status indicator). Dew point temperature is the temperature at which the air reaches the state of saturation and water vapour starts to condensate.
-
Condensation control switch HYGRASREG® KW
€113.15The sensor device is installed on cooling ceilings, cooling or cold-water pipes and cooled surfaces, and has been designed to prevent the formation of condensation. It reliably detects the formation of dew by means of its humidity and temperature sensor (no conductivity measurement). Thanks to its measuring method of pro-dynamic cross-convection it yields precise measuring results (with LED status indicator). Dew point temperature is the temperature at which the air reaches the state of saturation and water vapour starts to condensate.
-
copy of Room humidity and temperature sensor or measuring transducer HYGRASGARD® FSFM-U
€264.21The HYGRASGARD® FSFM / FSFTM room humidity transmitter with in-wall housing is used for measuring the relative humidity and temperature of the air. It converts the measured values into a standard signal of 0-10 V.
A digital, long-term stable sensor is used for humidity and temperature measurement. Relative humidity [% r.H.] is the quotient of water vapour partial pressure divided by the saturation vapour pressure at the respective gas temperature.
-
copy of Room pendulum humidity and temperature sensor HYGRASGARD® RPFF - 25/ RPFTF - 25
€466.47Calibratable HYGRASGARD® RPFF - 25 / RPFTF - 25 pendulum room humidity and temperature measuring transducer with pluggable metal sinter filter, housing made of impact resistant plastic, with/without optional display. The sensor device measures relative humidity and/or air temperature and converts the measurands into a standard signal of 0-10 V or 4...20 mA. It supports with four switchable temperature ranges.
-
copy of Screw-in/ smoke gas temperature measuring transducer THERMASGARD® RGTM2-U 100/80mm
€300.08The calibratable THERMASGARD® RGTM 2 flue gas screw-in temperature measuring transducer with eight switchable measuring ranges, neck tube, exchangeable spring-mounted measuring insert, straight protective tube, connecting head made of aluminium and continuous output for the detection of high temperatures in gaseous media, e.g. for exhaust air or flue gas temperature measuring.
-
Dew point control switch HYGRASREG® TW
€174.91The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€228.28The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€136.05The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€189.43The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€141.23The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€161.95The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Dew point control switch HYGRASREG® TW
€215.35The HYGRASREG® TW dew point control switch is installed on cooling or cold-water piping, or on cooled surfaces. It reliably detects the formation of condensation by means of its humidity and temperature sensor (no conductivity measurement) and provides precise measuring results thanks to its patented measuring method of pro-dynamic cross-convection (Patent No. DE 102012 015 726.6). The sensor device is available with/without optional display.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€25.51The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€37.62The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€25.51The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€37.62The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€25.51The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€37.62The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€25.51The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€37.62The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.
-
Differential pressure switch / differential pressure controller PREMASREG® DS
€57.00The mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale.