Frost protection thermostat THERMASREG® FST-xx D

€160.95
Tax included

Mechanical frost protection thermostat/ frost monitor THERMASREG® FST with switching output, fully-active sensor rod, with automatic reset or with mechanical locking – with manual reset is available with capillaries in lengths of 0.6 m, 1.8 m, 3 m, 6 m, 12 m. The frost protector is suitable for air or water-side temperature monitoring at heat exchangers, water circulation systems and heating registers to prevent freezing up and to avoid frost damage, e.g. in ventilation and air conditioning ducts. All devices are intrinsically safe and are equipped with sensor breakage detection. In the event of damage to the capillary membrane system, the frost sensor automatically switches to the heating function. The FST 3 can also be used to monitor liquids.

THERMASGARD®
Function
Length of capillary tube
Quantity

Operating difference

2 ± 1 K (3.6 ± 1.8 °F)

Switching capacity

10 (2) A, AC 250 V;

because of gold-plated switching contacts

also switching of signal voltages < 24 V

Contact

dust-proof micro switch

as single-pole potential-free changeover contact

Reproducibility

± 0.5 K (± 0.9 °F)

Setting range

–10...+15 °C/ +14 °F...+59 °F,

factory setting to w = +5 °C (+41 °F)

Ambient temperatures

maximum operating temperature: +70 °C (+158 °F)

minimum operating temperature: w + min. +2 °C (min. +3.6 °F)

storage/ transport: –30...+70 °C (–22...+158 °F)

capillary: max. +150 °C (+302 °F)

Permissible medium

Air

Process connection

by mounting clamps MK- 05 - K

(included in the scope of delivery)

Sensor responding length

approx. 40 cm

Mounting position

arbitrary

Electrical connection

0.14 - 2.5 mm²

Housing

plastic, UV-stabilised,

material polyamide, 30 % glass-globe reinforced,

with quick-locking screws

(slotted/ Phillips head - combination),

colour traffic white (similar to RAL 9016)

Housing dimensions

126 x 90 x 50 mm (Tyr 2)

Cable gland

M 16 x 1.5; including strain relief

Length of capillary tube

12.0 m

Resetting

automatic

Other materials

mechanical sheet metal parts: galvanised steel

capillary tube: copper

capillary tube filling: R 507

switching contacts: Ag/ Ni (90%/ 10%) gold-plated (3 m)

Protection class

I (according to EN 60 730-1)

Protection type

IP 65 

1102-1025-0102-000

16 same category products: