Surface contact/ tube contact temperature measuring transducers THERMASGARD® ALTM2-I VAQ

€464.08
Tax included

Calibratable THERMASGARD® ALTM 2 - VA tube contact temperature measuring transducer with eight switchable measuring ranges, external sensor, continuous output, rugged housing in V4A stainless steel, with cable gland or M12 connector according to DIN EN 61076-2-101.

The surface-contact transmitter is used for temperature detection on lines, pipes (e.g. cold and hot water) or on heating sections for heating system control.

THERMASGARD®
Output model
Output
Quantity

Power consumption

< 1,0 VA/ 24 V DC

< 2,2 VA/ 24 V AC

Voltage supply

15...36 V DC

depending on working resistance, residual ripple stabilised ± 0.3 V

Working resistance

Ra (ohm) = (Ub -14 V)/ 0.02 A for I variant

Temperature deviation

typically ± 0.2 K at +25 °C

Sensor

Pt1000, DIN EN 60751, class B

(Perfect Sensor Protection)

Connection type

2-wire connection

Ambient temperature

Measuring transducer –30...+70 °C

Process connection

endless metal strap and metal tightener

(included in scope of delivery)

Insulating resistance

100 MΩ,

at +20 °C (500V DC)

Strap dimensions

Ø = 13 - 92 mm (¼ - 3"), L = 300 mm

Electrical connection

0.14 - 1.5 mm² via terminal screws

Housing dimensions

143 x 97 x 61 mm (Tyr 2E)

Output

4...20 mA

Permissible air humidity

< 95 % r. H., non-precipitating air

Sensor protection

pipe feeder, stainless steel V4A (1.4571), Ø = 6 mm,

nominal length NL = 50 mm, cable entry stamped

Protection class

III (according to EN 60 730)

Protection type housing

IP 65 (according to EN 60 529)

Housing tested, TÜV SÜD, Report No. 713160960B (Skadi2)

Measuring ranges

multi-range switching with 8 switchable measuring ranges,

(other ranges optional)

detached sensor variant: Tmax over 100 °C, operating range –50... +150 °C;

with manual zero point correction (± 10 K)

Cable connection

M12 connector

(male, 5-pin, A-code)

according to DIN EN 61076-2-101

Housing

stainless steel V4A (1.4571),

with non-distortion cover bolting,

impact-resistant, high EMI shielding,

corrosion, temperature, UV and weathering resistant

sensor cable

silicone, SiHF, 2 x 0.25 mm², KL = 1.5 m (other lengths and

range limits optional, e.g. PTFE leads up to +250 °C

or glass fibre with steel wire mesh up to +350°C)

Protection type (sensor)

IP 65

2001-2151-2100-001