Permissible working resistance (at nominal voltage)
RL = 600 Ω for I-variant
Response time
< 5 ms
Measuring principle
ceramic measuring cell
Media temperature
–15...+80 °C
Pressure connection
screw pipe connection for 6 mm pipe
(G ⅛ " - 27 NPT internal thread)
Type of pressure
differential pressure
Class
0.5 %
Total error
< 1.3 %
System pressure
máx. 25 bar (P1 + P2)
Output signal
4-20 mA, 3-wire connection
Bursting pressure
1.5 x system pressure
Medium
liquid or gaseous
Measuring range
0...10 bar
Insulating resistance
100 MΩ,
at +20 °C (500V DC)
Electrical connection
0.25 - 1.5 mm², via plug-in connector DIN EN 175301-803-A
Housing
stainless steel 1.4305
Connecting head
angle plug connector DIN EN 175301- 803 - A
Installation
installation arbitrary
Bursting pressure
1.5 x Systemdruck
Medium contacting parts
INOX 1.4305, ceramics, sealing material EPDM
Protection class
III (according to EN 60 730)
Measuring range pressure
0... 10 bar
Protection type
IP 65 (according to EN 60 529) with receptacle mounted
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Optional
Display module, made of plastic, polyamide material,
black colour, extra height: approx. 73 mm, pluggable,
factory-calibrated and configured,
for displaying the differential pressure
Pressure port
Rohrverschraubung für 6 mm -Rohr
(G1/8 " - 27 NPT Innengewinde)
Class
0,5 %
Total error
< 1,3 %