Permissible working resistance (at nominal voltage)
RL = 600 Ω for I-variant
Response time
< 5 ms
Measuring principle
ceramic measuring cell
Media temperature
–15...+80 °C
Pressure connection
screw pipe connection for 6 mm pipe
(G ⅛ " - 27 NPT internal thread)
Type of pressure
differential pressure
Class
0.5 %
Total error
< 1.3 %
System pressure
máx. 25 bar (P1 + P2)
Output signal
4-20 mA, 3-wire connection
Bursting pressure
1.5 x system pressure
Medium
liquid or gaseous
Measuring range
0... 6 bar
Insulating resistance
100 MΩ,
at +20 °C (500V DC)
Electrical connection
0.25 - 1.5 mm², via plug-in connector DIN EN 175301-803-A
Housing
stainless steel 1.4305
Connecting head
angle plug connector DIN EN 175301- 803 - A
Installation
installation arbitrary
Bursting pressure
1.5 x Systemdruck
Medium contacting parts
INOX 1.4305, ceramics, sealing material EPDM
Protection class
III (according to EN 60 730)
Measuring range pressure
0... 6 bar
Protection type
IP 65 (according to EN 60 529) with receptacle mounted
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU
Optional
Display module, made of plastic, polyamide material,
black colour, extra height: approx. 73 mm, pluggable,
factory-calibrated and configured,
for displaying the differential pressure
Pressure port
Rohrverschraubung für 6 mm -Rohr
(G1/8 " - 27 NPT Innengewinde)
Class
0,5 %
Total error
< 1,3 %