Pressure, differential pressure and volume flow measuring transducers PREMASGARD® 111x

€238.70
Tax included

The calibratable, compact pressure measuring transducers of the PREMASGARD® 111x series support eight switchable measuring ranges (eight devices in one), arew available with or without optional display and serve to measure above-atmospheric, below-atmospheric or differential pressures as well as volume flow in air.

The piezoresistive measuring element is temperature-compensated and guarantees a high degree of reliability and accuracy. The pressure transmitters feature a configurable offset and a button for manual zero adjustment. Applications are found in cleanroom, medical and filter engineering, in ventilation and air conditioning ducts, in spray booths and in large-scale catering facilities, in filter monitoring and level measuring or frequency converter triggering.

Output
Display
Pressure range
PREMASGARD® / PREMASREG®
Quantity

Power consumption

< 1 W at 24 V DC; < 2 VA at 24 V AC

Voltage supply

15...36 V DC

depending on working resistance, residual ripple stabilised ± 0.3 V

Working resistance

Ra (ohm) = (Ub -14 V)/ 0.02 A for I variant

Measuring function

Differential pressure, volume flow (square root output signal)

Current consumption

< 20 mA

Measuring ranges

multi-range switching with 8 switchable measuring ranges

Media temperature

-20...+50°C

Pressure connection

with connection nozzles for pressure hose Ø 6 mm

Type of pressure

differential pressure

Zero point offset

± 5 % of final value

Above- below-pressure

max. 5 x pressure range

Medium

clean air and

non-aggressive, non-combustible gases

Signal filtering

switchable 1 s/ 10 s

Output

4...20 mA

Electrical connection

2- or 3-wire connection

0.14 - 1.5 mm² via terminal screws

Output signal

4...20 mA

Cable connection

cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or

M12 connector according to DIN EN 61076-2-101 (optional on request)

Cable gland

M 16 x 1.5, including strain relief, exchangeable,

max. inner diameter 10.4 mm

Long-term stability

± 1 %/ year

Hysteresis

0.3 % of final value

Media contacting parts

ms, Ni, Nylon, PU, Si, PVC with plasticisers

Temperature drift values

± 0.1 % of final value/ °C

Linearity

< ± 1 % of final value

Air humidity

< 95 % r. H., non-precipitating air

Accuracy

(10000 Pa): ± 50 typically Pa

compared to the calibrated reference device

Protection class

III (according to EN 60 730)

Protection type

IP 65 (according to EN 60 529)*

Standards

CE conformity,

electromagnetic compatibility according to EN 61326,

according to EMC Directive 2014/ 30/ EU

Measuring range pressure

0 ... +4000 Pa / -4000 ... +4000 Pa

0 ... +6000 Pa / -6000 ... +6000 Pa

0 ... +8000 Pa / -8000 ... +8000 Pa

0 ... +10000 Pa / -10000 ... +10000 Pa

Housing

plastic, UV-stabilised,

material polyamide, 30 % glass-globe reinforced,

with quick-locking screws

(slotted/ Phillips head - combination),

colour traffic white (similar to RAL 9016),

housing cover for display is transparent !

1301-1112-2060-000

16 same category products: