Input side
Supply terminals A1 - A2 (L/+) - (N/-)
Supply voltage 24 - 240 V AC/DC
Tolerance -15 %; +10 %
Power consumption 2 VA
Measure circuit
Measuring terminals T1 - T2 (the connection for the measuring range must be effected via a separate cable)
Measuring voltage ca. 2.5 V DC
Upper resistance value 3.3 kΩ
Lower resistance value 1.8 kΩ
Sensor PTC resistor / thermal contact (can be switched to switch at the front)
Sensor malfunction signal LED red
Accuracy
Repeatability < 0.5 %
Switching difference +/- 5 %
Temperature dependency < 0.1 % / °C
General data
Mechanical life 3 x 107
Electric life 0.7 x 105
Dielectric strength between coil and contacts 2.5 kV
Ambient temperature -20°C … +55°C
Storage temperature -30°C … +70°C
Mounting position any
Fixing DIN rail EN 50022-35
Protection class of Front IP 40
Voltage limitation class III
Degree of contamination 2
Connection cross-section 2.5 mm2
Weight 77 g
Standards EN 60730-2-9, EN 61010-1
Output side
Number of contacts 2 changeover contacts
Switching voltage 250 V AC / 24 V DC
Switching current / contact material 8 A / AC1 / AgNi
Output display LED red
min. DC switching capacity 500 mW
Maximum peak current 10A / < 3s
Switching capacity 2000 VA / AC1 / 192 W / DC