Control and signaling devices

Active filters

  • Installation Relay ISR1-316/24

    €39.68

    The installation relay ISR1-316 contains 3 changeover

    contacts for a 16 A / 250 V AC load.

    The narrow, 17.5-mm DIN housing saves space in the

    switching cabinet and has a high switching capacity.

    It can be operated with a supply voltage of 230 V AC

    or 24 V AC/DC and has a built-in protection diode and

    interference suppression capacitor. 

  • Installation relay ISR2-216

    €45.78

    The installation relay ISR2-216 contains 2 changeover contacts for a load of 16A / 250 V AC, which can be controlled separately.  

    The 17.5 mm narrow DIN housing saves space in the control cabinet, so a circuit only needs 8.75 mm.

    Each individual relay can be operated separately with the supply voltages 230 V AC and 24 V AC/DC. They have a built-in protection diode and interference suppression capacitor.

  • Inverse isolating amplifier RB6250

    €241.60

    The universal isolating amplifier RB 6250 is used for galvanic isolation and conversion of industry standard signals with an inverse characteristic. It can be used flexibly thanks to the simple range switching of the 144 possible signal combinations, the new universal power pack and the compact design. The high level of reliability and safe separation are further features that make the RB 6250 unrivaled.

    The desired input and output measuring ranges to which the device is factory-calibrated can be specified with an order code. These can be easily reconfigured at any time using DIP switches. Subsequent readjustment or a measurement path comparison is possible using the zero/span potentiometers on the front.

  • Isolator without auxiliary power RH1011

    €85.46

    The loop-powered isolator RH 1011 electrically isolates

    0(4) ... 20mA standard signal circuits and transmits the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.0 V, the high level of accuracy and the compact design, the RH 1011 is the first choice in plant construction.

    The 12.5 mm narrow modular housing saves space in the control cabinet and facilitates installation thanks to the practical plug-in terminals.

  • Isolator without auxiliary power RH1012

    €127.66

    The loop-powered isolator RH 1012 electrically isolates

    0(4) ... 20mA standard signal circuits and transmits the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.0 V, the high level of accuracy and the compact design, the RH 1012 is the first choice in plant construction.

    Intelligent circuit technology and the consistent omission of highly integrated circuit components leads to an extremely long service life and reliability without falsification of the measurement signal.

  • Isolator without auxiliary power RH1021

    €101.29

    The loop-powered isolator RH 1021 electrically isolates 0(4) ... 20mA standard signal circuits and transmits the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.0 V, the high level of accuracy and the compact design, the RH 1000 is the first choice in plant construction.

    Intelligent circuit technology and the consistent omission of highly integrated circuit components leads to an extremely long service life and reliability without falsification of the measurement signal.

  • Isolator without auxiliary power RH1022

    €147.71

    The loop-powered isolator RH 1022 electrically isolates 0(4) ... 20mA standard signal circuits and transmits the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.0 V, the high level of accuracy and the compact design, the RH 1000 is the first choice in plant construction.

    Intelligent circuit technology and the consistent omission of highly integrated circuit components leads to an extremely long service life and reliability without falsification of the measurement signal.

  • Isolator without auxiliary power RH11010

    €77.02

    The loop-powered isolator RH 11010 electrically isolates 0(4) ... 20 mA standard signal circuits and transfers the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.5 V, the high level of accuracy and the compact design, the RH 11010 is the first choice in plant construction. The 6.3 mm narrow modular housing for 1 or 2 channels saves space in the control cabinet. The RH 11020 only requires a 3.0 mm DIN rail per channel. Intelligent circuit technology and the consistent omission of highly integrated circuit components leads to an extremely high MTBF, which means high long-term stability - without falsification of the measurement signal. 

  • Isolator without auxiliary power RH11020

    €112.90

    The loop-powered isolator RH 11020 electrically isolates 0(4) ... 20 mA standard signal circuits and transfers the measurement signal to the output with high accuracy. It thus avoids interference voltages being carried over and effectively suppresses interference. Due to the low internal voltage requirement of only 2.5 V, the high level of accuracy and the compact design, the RH 11020 is the first choice in plant construction. The 6.3 mm narrow modular housing for 1 or 2 channels saves space in the control cabinet. The RH 11020 only requires a 3.0 mm DIN rail per channel. Intelligent circuit technology and the consistent omission of highly integrated circuit components leads to an extremely high MTBF, which means high long-term stability - without falsification of the measurement signal. 

  • ISR1-316/L-230 Coupling module

    €69.41

    The ISR1-316/L contains 3 make contacts with advanced tungsten contacts. 

    Switching on lighting fixtures can result in very high inrush currents.

    A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).

    To avoid contact sticking, relays with a leading tungsten contact are used.

    This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.  

    The installation relay has a built-in protection diode and interference suppression capacitor. Supply voltage: 230VAC

  • ISR1-316/L-24 Coupling module

    €62.03

    The ISR1-316/L contains 3 make contacts with advanced tungsten contacts.

    Switching on lighting fixtures can result in very high inrush currents.

    A closing contact bounces 3-7 times until it closes completely. This creates an arc that can melt the contact surface. If the closed contact cools down, micro-welding can occur (contact sticks).

    To avoid contact sticking, relays with a leading tungsten contact are used.

    This allows switch-on peaks of 165 A / max. 20 ms for incandescent lamps, or 800 A / max. 200 µs for fluorescent lamps.  

    The installation relay has a built-in protection diode and interference suppression capacitor. Supply voltage: 24VAC/DC

  • Multifunction time relay ZRM103

    €67.09

    The multifunction time relay ZRM103 contains 3 changeover contacts for a load of 8 A / 250 V AC. The 17.5 mm narrow DIN housing saves space in the control cabinet with high switching and functional capacity. 10 functions: 5 with operating voltage, 4 with control contact, 1 function as a pulse relay. The time ranges can be set from 0.1s to 10 days. The multi-voltage power supply enables operation with all voltages from 12 V to 240 V AC / DC.

    3 changeover contacts 1x16A / 2x8A

    The device has 1 changeover contact with 16A/250VAC and 2 changeover contacts with 8A/250VAC

    Multi-voltage range

    The ZRM-103 includes a multi-voltage power supply. This means that it can be controlled with all voltages between 12 V and 240 V AC / DC.

  • Passive feed isolator RC58

    €98.12

    With the passive supply isolator RC 58, Relmatic expands the product range of compact and cost-effective interface technology modules.

     

    The passive power supply RC 58 is used to feed 2-wire measuring transducers. The 24 V supply from the control system is transmitted galvanically isolated to the 2-wire transmitter with a low voltage drop. Due to the high reliability, the extremely compact design and the cost-optimized construction, the RC 58 is the first choice in its class!

  • Passive isolating amplifier RH18-1

    €70.68

    With the RH 18 loop-powered isolator, Relmatic is expanding its product range of compact and cost-effective interface technology modules.

    The RH 18 loop-powered isolator is used for galvanic isolation of 0(4)... 20mA standard signals. Due to the high reliability, the extremely compact design and the cost-optimized construction, the RH 18 is the first choice in its class!

    Lots of useful details: The RH 18 can also be installed in inexpensive standard terminal boxes, which are often used for decentralized measuring points, thanks to the extremely low overall depth of just 60mm. The 11.2 mm narrow modular housing for 1 or 2 channels saves a lot of space on the DIN rail.

  • Passive isolating amplifier RH18-2

    €97.06

    With the RH 18 loop-powered isolator, Relmatic is expanding its product range of compact and cost-effective interface technology modules.

    The RH 18 loop-powered isolator is used for galvanic isolation of 0(4)... 20mA standard signals. Due to the high reliability, the extremely compact design and the cost-optimized construction, the RH 18 is the first choice in its class!

    Lots of useful details: The RH 18 can also be installed in inexpensive standard terminal boxes, which are often used for decentralized measuring points, thanks to the extremely low overall depth of just 60mm. The 11.2 mm narrow modular housing for 1 or 2 channels saves a lot of space on the DIN rail.

  • Potentiometer transducer RR4310

    €122.39

    With the potentiometer transmitter RR 4310, Relmatic expands the product range of interface technology components with the highest functionality and reliability.

     

    The RR 4310 potentiometer transmitter is used for galvanic isolation and conversion of potentiometric control signals. It can be used flexibly thanks to the simple range switching of the output signal, the new universal power pack and the compact design. The high level of reliability and safe isolation are further features that make the RR 4310 unrivalled.

     

    The signal configuration can be set with a DIP switch. Subsequent readjustment or a measurement path comparison is possible using the zero/span potentiometers on the front.

  • Power divider RC52100

    €112.89

    The power supply isolator RC 52100 serves to feed and isolate 2- and 3-wire measuring transducers. It supplies the transmitter with auxiliary power and transmits the measurement signal to the output with a high level of accuracy, with electrical isolation. It can be used flexibly thanks to the calibrated measuring range switchover and the compact design. The high level of reliability and safe isolation are additional features that contribute to trouble-free system operation. With the RC 52100, the input and output ranges can be easily switched using a DIP switch. Subsequent readjustment is not necessary thanks to the calibrated measuring range switchover. 

  • Power separator HART RC52500

    €121.32

    The RC 52500 supply isolator is used to supply and isolate intelligent 2-wire measuring transducers. It supplies the transmitter with auxiliary power and transmits the measurement signal to the output with a high level of accuracy, with electrical isolation. In addition to the analogue signal, the RC 52500 also transmits data protocols for HART transmitters. It enables bi-directional communication with the field device from any point in the cabling. Pluggable switching combs for the auxiliary power supply ensure quick and cost-effective assembly. The 6.3 mm narrow modular housing saves considerable space in the control cabinet on the DIN rail. The RC 52500's switched-mode power supply, which has been optimized in terms of efficiency, significantly reduces the device's self-heating.

  • PSA Mini LED

    €44.31

    The devices of the PSH-Mini series were developed to protect sensitive devices and electronics in connection with upstream class I+II devices.

    The PSH Mini includes metal oxide varistors and gas-filled spark gaps for protection in the TN-S network. The compact device signals a defect via an LED. 

  • PSA Mini S

    €45.37

    The devices of the PSH-Mini series were developed to protect sensitive devices and electronics in connection with upstream class I+II devices.

    The PSH Mini includes metal oxide varistors and gas-filled spark gaps for protection in the TN-S network. The compact device signals a defect via a signal tone generator.

  • Resistance transmitters RR41

    €112.89

    The RR 41 resistance measuring transducer converts the measured values ​​from resistance sensors into standard signals and makes them available potential-free at the output.

     

    For applications in which only one measuring range is required, the RR 41 transmitter offers a cost-effective alternative.

    A switching comb for the power supply ensures quick and easy assembly. The 11.2 mm wide modular housing saves a lot of space on the DIN rail. If necessary, a measuring distance can be adjusted using the zero/span potentiometers behind the front cover.

  • Shunt isolation amplifier RS7200

    €236.43

    The isolation amplifier RS ​​7200 is used for galvanic isolation and conversion of bipolar and unipolar shunt voltages. It can be used flexibly thanks to the simple measuring range switchover, the new universal power pack and the compact design. The high level of reliability and safe separation are further features that make the RS 7200 unrivaled.

     

    The desired input and output measuring ranges to which the device is factory-calibrated can be specified with an order key. These can be easily reconfigured at any time using DIP switches. Subsequent readjustment or a measurement path comparison is possible using the zero/span potentiometers on the front

  • Shunt isolation amplifier RS75000

    €162.59

    The RS 75000 shunt isolating amplifier is used for galvanic isolation and conversion of bipolar and unipolar mV voltages, such as are often used in current measurement

    occur with shunt resistors or other applications. It can be used flexibly thanks to the calibrated measuring range switchover and the compact design. The high level of reliability and safe separation are further features that make the RS 75000 unrivalled. The desired input and output measuring ranges to which the device is factory-calibrated can be specified with an order key. These can be easily reconfigured at any time using DIP switches

  • Signal isolating amplifier RN2400

    €126.61

    The RN 2400 standard signal isolating amplifier is used for galvanic isolation and conversion of 0...20 mA, 4...20 mA and 0...10 V industry standard signals. The high level of reliability and the cost-optimized design are essential features that contribute to economical plant operation.